Slow-speed paper bowl machine routine maintenance

Feb 11, 2026

Leave a message

Daily maintenance of slow dishwashers (35 to40 pieces per minute or less in production) is essential to ensure the steady operation of the equipment, prolong its life and reduce failure rate. The main points of maintenance include cleaning, lubrication, tightening, adjustment, consumable replacement, etc. A maintenance plan for the system needs to be prepared according to the structural characteristics of the equipment (e.g. mechanical transmission, heating modules, electrical control, etc.). Here are the specific maintenance plans:

 

I. Daily maintenance (after production)
1.Cleaning and Dusting
Key areas:
Forming molds: Use a soft brush to clean any scraps of paper or coating (such as PE particles) from the mold surface to prevent blockage and affect bowl shape accuracy.
Heating modules: Use compressed air to blow dust off the surface of the heating plates (such as the heat sealing areas) to prevent local overheating that causes coating to burn.
Transmission chains/ Belt: Wipe the chain and belt surfaces with dry cloth for oil stains and paper dust to prevent slipping or wear.
Electrical control boxes: use vacuum cleaners to clean dust inside the box (especially precision components such as phase lock ring and servo drives) to avoid short circuit or poor contact. Note:
Do not rinse the equipment directly with water or corrosive detergent to prevent dampness of electrical components or rust of metal parts.
When cleaning the mold, wear cutting gloves to avoid being scratched by mold edges.

 

2.Lubrication and Maintenance
Lubrication Points:
Chain: Add specific chain oil to the connecting point between the chain roller and pin shaft, dropping 3-5 drops per shift to reduce wear and tear.
Bearing: lithium-based lubricating grease is applied to spindle bearing, transmission shaft bearing, etc.. Replenish every 2 weeks.
Guide Rails: Spray dry lubricant on the surface of straight guide rail to reduce sliding friction. Note:
Lube should be of food-grade quality to prevent contamination of paper bowl.
Avoid excessive lubrication, which can cause oil to drip into paper bowl or heating module, posing a safety risks.

 

3.Enhanced inspections
Scope of inspection:
Mold Fixation Bolts: use torque wrench to check whether the mold installation bolts are loose.
Transmission Components: check whether the fixed screws of pulley, gearbox and other parts are loose, to prevent component displacement due to vibration.
Electrical connection: Check whether the wiring terminals of electrical components such as sensors and solenoid valves are loose to avoid poor contact and possible failure.

Slow Speed Paper Bowl Machine

II. Weekly maintenance (every 5 working days)
1. Calibration heating assembly
Operational steps:
The surface temperature of the heating plate is measured using an infrared thermometer and compared with the setting of the device (e.g., the heat sealing temperature is set at 180 degrees Celsius). The error should ≤ 5°C.
If the temperature deviation is too large, adjust temperature controller parameters or check the heating tube for aging (this requires professional operation).
Wash the oxide layer on the surface of the heating tube (gently grind with fine sandpaper) to restore heating efficiency. Note:
power supply must be disconnected before calibration to avoid the risk of electrocution.
heating tube typically have a service life of 2-3 years and need to be replaced periodically (e.g. the ZW-LII type heating tube service life of about 8,000 hours).

 

2.Transmission System Inspections
Inspection Contents:
Belt tension: Measure the tension of a belt with belt tension gauge. If the tension is insufficient, adjust the tensioning wheel.
Chain wear: Measuring the pitch of a chain. If wear exceeds 5%, replace the chain.
Gear meshing: Check the meshing of gears in the gearbox. If there are indentations or abrasions, please replace the gear pairs.

 

3.Power System Inspection
Inspection items:
Sensor accuracy: The feedback value of photoelectric sensors and position sensors is tested using standard measuring tools. The error should ≤ 0.1mm.
Electromagnetic valve response: manually trigger solenoid valve (such as the pneumatic tool change valve), check that the action is quick and nonstick.
Grounding resistance: Measurement of grounding resistance of equipment using a grounding resistance tester.

Send Inquiry